Line 2: Line 2:


I (re-)discovered that auto-read starts approximately 200-ish master clocks after NMI starts. I assumed that I could start waiting for it to finish immediately in NMI and was wrong. This delay should be mentioned somewhere, but here, or on [[Errata]]? (or both?) —[[User:Lidnariq|Lidnariq]] ([[User talk:Lidnariq|talk]]) 08:03, 25 May 2022 (UTC)
I (re-)discovered that auto-read starts approximately 200-ish master clocks after NMI starts. I assumed that I could start waiting for it to finish immediately in NMI and was wrong. This delay should be mentioned somewhere, but here, or on [[Errata]]? (or both?) —[[User:Lidnariq|Lidnariq]] ([[User talk:Lidnariq|talk]]) 08:03, 25 May 2022 (UTC)
I'll add a note for it here - [[User:NovaSquirrel|NovaSquirrel]] ([[User talk:NovaSquirrel|talk]]) 18:31, 25 May 2022 (UTC)

Latest revision as of 18:31, 25 May 2022

HVBJOY

I (re-)discovered that auto-read starts approximately 200-ish master clocks after NMI starts. I assumed that I could start waiting for it to finish immediately in NMI and was wrong. This delay should be mentioned somewhere, but here, or on Errata? (or both?) —Lidnariq (talk) 08:03, 25 May 2022 (UTC)

I'll add a note for it here - NovaSquirrel (talk) 18:31, 25 May 2022 (UTC)