Timings of the S-SMP DSP envelope and gain.
ADSR Envelope Timings
ADSR Attack
|
A |
Time (ms)
|
$0 |
4100
|
$1 |
2600
|
$2 |
1500
|
$3 |
1000
|
$4 |
640
|
$5 |
380
|
$6 |
260
|
$7 |
160
|
$8 |
96
|
$9 |
64
|
$A |
40
|
$B |
24
|
$C |
16
|
$D |
10
|
$E |
6
|
$F |
0
|
|
ADSR Decay
|
D |
Time (ms)
|
0 |
1200
|
1 |
740
|
2 |
440
|
3 |
290
|
4 |
180
|
5 |
110
|
6 |
74
|
7 |
37
|
|
ADSR Release
|
R |
Time (ms) |
R |
Time (ms)
|
$00 |
Infinite |
$10 |
1200
|
$01 |
38000 |
$11 |
880
|
$02 |
28000 |
$12 |
740
|
$03 |
24000 |
$13 |
590
|
$04 |
19000 |
$14 |
440
|
$05 |
14000 |
$15 |
370
|
$06 |
12000 |
$16 |
290
|
$07 |
9400 |
$17 |
220
|
$08 |
7100 |
$18 |
180
|
$09 |
5900 |
$19 |
150
|
$0A |
4700 |
$1A |
110
|
$0B |
3500 |
$1B |
92
|
$0C |
2900 |
$1C |
74
|
$0D |
2400 |
$1D |
55
|
$0E |
1800 |
$1E |
37
|
$0F |
1500 |
$1F |
18
|
|
Gain Timings
The odd linear gain rates are equivalent to the attack envelope rates (except for the fastest entry). The exponential decrease gain is equivalent to the release envelope.
GAIN
|
Decrease Linear |
Decrease Exponential |
Increase Linear |
Increase Bent
|
V |
Time (ms) |
V |
Time (ms) |
V |
Time (ms) |
V |
Time (ms)
|
$80
|
Infinite
|
$A0
|
Infinite
|
$C0
|
Infinite
|
$E0
|
Infinite
|
$81
|
4100
|
$A1
|
38000
|
$C1
|
4100
|
$E1
|
7200
|
$82
|
3100
|
$A2
|
28000
|
$C2
|
3100
|
$E2
|
5400
|
TODO finish this table
|